Page 266 - EZ Catalog 18
P. 266

1   Demonstration Model Difficult Airway Management
                                                                                           Compact table-top design, anatomical accuracy and a variety of Difficult Airway Management
                                                                                           settings. Ideal for demonstration of skills and devices.


                                                                                           Features:
                                                                                              n Anatomically correct airway
                                                                                              n The incisors break when excessive force is applied.
                                                                                              n Successful tube tip placement can be confirmed by indicators.
                                                                                           Training Skills:
                                                                                              n Airway opening techniques (head tilt, jaw thrust)
                                                                                              n Bag-Valve-Mask ventilation
                                                                                              n Pre-intubation airway assessment
                                                                                              n „Sniffing position“
                                                                                              n Pressurization of external larynx to improve the laryngeal view
                                                                                              n Oral/Nasal Intubation
                                                                                              n Use of oropharyngeal airway (OPA)
                                                                                              n Use of nasopharyngeal airway (NPA)
                                                                                              n Use of laryngeal mask airway
                                                                                              n Use of video laryngeal scope
                                                                                              n Confirmation of successful ventilation by indicators.
                                                                                              n Feedback of incorrect procedures including esophagus intubation and unilateral intubation
                                                                     1                        n Securing the tube in place with tape or Thomas™ endotracheal tube holder
                                                                                           Comes with carrying bag, lubricant, 3 replacement incisors and instructional manual.
                                                                                              n Ref.no. R16061





























        264