Page 249 - EZ Catalog 18
P. 249

1   CVC Insertion Simulator III
               The CVC Insertion Simulator III provides training in a sequence of procedural skills from the needle
               insertion to catheter placement, including Seldinger technique. It provides training opportunities
               in an array of procedural skills from determining the insertion site to placement of the catheter
               without interruption. Both landmark and ultrasound-guided catheterization are possible in one pad.
               Features:
                   n Repeated insertion
               The improved frictionless tissue of the pad allows Seldinger technique and repeated insertion and
               removing of the catheter with less needle marks left on the surface of the pad.
                   n Both landmark and ultrasound-guided CVC:
               The anatomically correct structure facilitate training in both landmark and ultrasound-guided CVC.
                   n Mechanical complications, such as arterial puncture and pneumothorax can be simulated for
                  training.
                   n New material
               The close-to-human tissue material of the pad provides true-to-life sensation inserting the catheter.
                   n Realistic venous collapse
               The vein collapses under the pressure of the ultrasound probe.
               The pad shows the following anatomical structures:
                   n Internal jugular vein & carotid artery
                   n Subclavian vein & artery
                   n Superior vena cava
                   n Ribs
                   n Sternum
                   n Lung
               Training Skills
                   n Ultrasound-guided CVC
                   n Landmark guided CVC
                   n Ultrasound-guided venous access
                   n Prevention of mechanical complications
               The new and innovative material does
               provide an incredible realism and tactile
               excellence as well as ultrasound imaging
               quality. However, due to its special
               material, the injection pad has a limited
               shelf life once it is unpacked.                                                          1
                   n Ref.no. R16052












                                                                                                                                                                        247